L180 Enclosed Logger (USB)
DESCRIPTION
The L180 Enclosed Logger is a powerful control unit and a fully programmable data logger with 250 MB memory. USB logging is optional and increases internal memory to 500MB, it collects data from devices such as a controller and can be used in a number of applications.
Specifications
Upgrades
Logging
- 250 MB log memory (500 MB + USB optional)
- Recording rates up to 1000 samples per second
- Fast ethernet download
- Includes standard i2 data analysis software (Pro Analysis upgrade available)
Entrances
- 10 (20 with I / O upgrade *) analog voltage inputs:
- 4 (8 *) x 0 to 5.46 V, 1.33 mV resolution 6 (12 *) x 0 to 15.0 V, 3.66 mV resolution
- 4 (8 with I / O upgrade) analog temperature inputs
- 0 to 15 V, 3.66 mV resolution
- 4 digital inputs
- 2 switch inputs
- 4 speed inputs
Outputs
- 6 low-side outputs PWM or switching operation
- 1.0 A max., Current limited and thermally overload safe
expander
- Compatible with the expanders E816 and E888 (for the full range of functions)
- VIM and SVIM
Internal sensors
- 3-axis accelerometer, detection range: +/- 5G
- Temperature sensor
- Sensor supply voltage
- Battery voltage
communication
- 4 configurable CAN buses with individually programmable CAN bus speeds.
- One can be used for RS232 reception. Only 2 of the CAN buses support VIM / SVIM expanders.
- 2 dedicated RS232 ports
Power supply
- Operating voltage: 6 to 32 V DC
- Operating current: 0.4 A typical at 14 V (without sensor currents)
- Reverse polarity protection
- Battery transient protection
Sensor supply currents
- 5 V sensor supply: maximum 0.25 A.
- 8 V sensor supply: maximum 0.25 A.
operating temperatur
- Inside: -20 ° C to 80 ° C
- Typical ambient temperature range in free air: -20 ° C to 65 ° C
Physically
- Size: 134.5 x 103.9 x 20.2 mm without connector
- Weight 343 g
- 1 x 79-pin Autosport connector
PriceFrom CHF4,179.05